Working Theory
Semiconductor lasers are stacked with ultra-micro semiconductor laser chips. The basic treatment principle is biological effect. The 808nm laser emitted by this machine is easily absorbed by colored hair follicles without damaging the epidermal tissue. The energy emitted by the light is absorbed by hair and pigments i hair follicles. After being converted into heat, the temperature of the hair follicles is increased. When the temperature rises to a certain level, the hair follicles will be irreversibly damaged. After a period of time, the damaged hair follicles will be removed with the body's metabolism to achieve the purpose of permanent hair removal. Modern design, stable output, short exposure time, good effect of permanent hair removal, high safety.
Treatment Course
Underarm, Face: Treatment interval---4-6 weeks;
Arms and legs, body: Treatment Interval----4-6 weeks;
Treatment Period: 4-6 times.
***Depending on the hair growth cycle and the treatment site, 28 days is recommended as a course of treatment, and 4-6 courses are enough.
***Under normal circumstances, users can check and receive more treatment within 4-6 weeks after surgery. According to different treatment effects, personal hair growth cycle, this period will be different.
***If no more treatment is needed, the user should be checked again after 3-4 months or if there is hair regrowth in the treated area.
***If part of the hair is removed, the user should receive a treatment check again after 4-6 weeks if necessary.
***If no changes are observed, the treatment parameters need to be changed, multiple treatments, and the interval time increased to allow new hair growth in the treated area. New growth in different parts of the body (growth cycle), different individuals (gender, hormones) are different.
Suggested Parameters
The following suggestions are for reference only, and customers in different regions should make reasonable adjustments.
1. Single Point Treatment
Set the low frequency to 1Hz and set the higher energy at the same time. The machine is set with factory default parameters, and the user can adjust it according to different situations, but please adjust the energy instead of frequency. In this mode, the pulse width will be automatically adjusted when you adjust the energy.
500W parameters, 300W energy plus 80% pulse width unchanged
2. Sliding Therapy
Set the frequency to 6HZ and set a lower energy. When using this treatment method, the therapist does not need to adjust the parameters, but only needs to choose the number and time of treatment according to the patient's feeling.
500W parameters, 300W energy plus 80% pulse width unchanged
Treatment parameter is adjusted by following principles:
Pulse width at 80ms:
Power from 6-20J/cm2 adjustable;
Frequency from 1-5Hz adjustable.
Pulse width at 120ms:
Power from 6-30J/cm2 adjustable;
Frequency from 1-3Hz adjustable.
Pulse width at 160ms:
Power from 8-40J/cm2 adjustable;
Frequency from 1-2Hz adjustable.
Pulse width at 200ms:
Power from 10-50J/cm2 adjustable;
Frequency from 1-2Hz adjustable.
Power and Frequency will change based on different pulse width.